Volume 12, February 2020
ISSN 1462-236X
ISBN 978-1-910643-94-5
F. Campos1, Dr. E. de Villiers1, S. Cammelli2
1ENGYS Ltd., UK
2BMT Fluid Mechanics Ltd., UK
https://doi.org/10.59972/c20013cz
Keywords: Compressible Flow, Pressure Wave, Numerical Simulation, Railway, Tunnel
BMT Fluid Mechanics conducted a comprehensive flow study on the effectiveness of a pair of Tuned Liquid Column Dampers (TLCDs) aimed at mitigating wind-induced accelerations in a high-rise building. study successfully combined Computational Fluid Dynamics (CFD) with physical model tests performed at the 6 degree-of-freedom shake table facility located at the Department of Civil Engineering of the University of Bristol.
The original TLCD concept discussed in this work was proposed at the early design stages of a slender 42-storey high-end residential building located in the Middle East. On-site full-scale measurements and High Frequency Force Balance (HFFB) wind tunnel tests performed by BMT Fluid Mechanics showed that the highest occupied floors could experience excessive wind-induced motion. Depending on the inherent damping of the finished structure, this motion had the potential to exceed standard occupant comfort criteria.
A new CFD methodology was developed to assess the performance of the TLCD design using the multi-phase Volume-of-Fluid (VOF) solver and dynamic mesh motion libraries available in the CFD software tool HELYX®. The damping effects introduced by the array of internal porous baffles in the TLCD were approximated using a Darcy-Forchheimer porosity model.
Comparisons of free-decay damping performance between CFD results and shake table experiments for a 1:20 scale model of a 3 baffles’ TLCD configuration were found to be satisfactory for design purposes. The results for the amplitude of the net forces acting on the TLCD, as well as the frequency response measured using the free-decay logarithmic decrement approach, confirmed that the proposed CFD methodology provides an accurate representation of real operating conditions.
The same CFD approach was successfully applied to model the full-scale TLCD device. With the introduction of a pair of identical purposely designed TLCDs, a 30% increase performance of the structural response of the 42-storey building to wind loading excitation was achieved.
[1] Modi, V.J. and Welt, F. (1987). Vibration Control Using Nutation Dampers. International Conference on Flow Induced Vibrations, London, England, pp. 369-376.
[2] Tamura, Y., Fuji, K., Sato, T., Wakahara, T. and M. Kosugi (1988). Wind Induced Vibration of Tall Towers and Practical Applications of Tuned Sloshing Dampers. Proceedings of Symposium/Workshop on Serviceability of Buildings, Ottawa, Canada, Vol. 1, pp. 228-241.
[3] Fujino, Y., Sun, L., Pacheco, B.M. and Chaiseri, P. (1992). Tuned Liquid Damper (TLD) for Suppressing Horizontal Motion of Structures. Journal of Engineering Mechanics, Vol. 118, No. 10, pp. 2017-2030. https://doi.org/10.1061/(ASCE)0733-9399(1992)118:10(2017).
[4] Kareem, A. (1990). Reduction of Wind Induced Motion Utilizing a Tuned Sloshing Damper. Journal of Wind Engineering and Industrial Aerodynamics, Vol. 36, pp. 725737. https://doi.org/10.1016/0167-6105(90)90070-S
[5] Kareem, A. (1993). Tuned Liquid Dampers: Past, Present, and Future. Proceedings of the 7th U.S. National Conference on Wind Engineering.
[6] Kareem, A. and M. Tognarelli (1994). Passive & Hybrid Tuned Liquid Dampers. Structural Engineering Forum, pp. 26-30.
[7] Sakai, F. et al. (1989). Tuned Liquid Column Damper - New Type Device for Suppression of Building Vibrations. Proceedings of International Conference on High Rise Buildings, Najing, China.
[8] Tamura, Y., Fujii, K., Ohtsuki, T. Wakahara, T. and R. Kohsaka (1995), Effectiveness of Tuned Liquid Dampers Under Wind Excitation. Engineering Structures, Vol. 17, No. 9, pp. 609-621. https://doi.org/10.1016/0141-0296(95)00031-2
[9] Tamboli, A. (2005). Manhattan’s Mixed Construction Skyscrapers with Tuned Liquid and Mass. Proceedings of CTBUH 7th World Congress, New York, pp. 16-19.
[10] Ha, M., Kim, D., Choi, H. I., Cheong C. and Kwon, S. H. (2012), Numerical and experimental investigations into liquid sloshing in a rectangular tank. Advances in Civil, Environmental and Materials Research (ACEM’ 12) Seoul, Korea.
[11] Yamamoto, K. and Kawahara, M. (1999), Structural oscillation control using tuned liquid damper. Computers & Structures, Vol. 71, No. 4, pp. 435-446. https://doi.org/10.1016/S0045-7949(98)00240-5
[12] Bulian, G., Souto-Iglesias, A., Delorme, L. and Botia-Vera, E. (2010), Smoothed particle hydrodynamics (SPH) simulation of a tuned liquid damper. Journal of Hydraulic Research, Vol. 48 (n. Spécia), pp. 28-39. https://doi.org/10.1080/00221686.2010.9641243.
[13] Chang, C-h., Wu, J-C., Cheng, C-M. and Lind Y-Y. (2010), Computational fluid dynamics simulation for horizontal movement tuned liquid column damper. Fifth International Symposium on Computational Wind Engineering (CWE2010), Chapel Hill, North Carolina, USA.
[14] Faltinsen, O. M., and Timokha, A. N. (2009), Sloshing. Cambridge University Press, Cambridge, UK.
[15] Ibrahim, R. A. (2005) Liquid Sloshing Dynamics: Theory and Applications. Cambridge University Press, New York.
[16] Cammelli, S., Li, Y. F. and Mijorski, S. (2016), Mitigation of wind-induced accelerations using Tuned Liquid Column Dampers: Experimental and numerical studies. Journal of Wind Engineering and Industrial Aerodynamics, Vol. 155, pp. 174181. https://doi.org/10.1080/00221686.2010.9641243.
[17] Kareem, A., and W.-J. Sun. (1987), Stochastic Response of Structure with Fluid Containing Appendages. Journal of Sound and Vibration, Vol. 119, No. 3, pp. 389-408. https://doi.org/10.1016/0022-460X(87)90405-6.
[18] Sun, L.M., Fujino, Y. and Koga, K. (1995). A Model of Tuned Liquid Damper for Supressing Pitching Motions of Structures. Earthquake Engineering & Structure Dynamics, Vol. 24, pp. 625-636.
[19] Yalla, S. (2001). Liquid Dampers for Mitigation of Structural Response: Theoretical Development & Experimental Validation. Ph.D. Thesis, University of Notre Dame, Indiana.
[20] Tait, M., EI Damatty, A.A., and Isyumov, N. (2004). Testing of Tuned Liquid Damper With Screens and Development of Equivalent TMD Model. Wind and Structures, Vol. 7, No. 4, pp. 215-234.
[21] Tait, M.J. (2008). Modelling and preliminary design of a structure-TLD system. Engineering Structures, Vol 30, pp. 2644–2655.
[22] Di Matteo, A., Lo Iacono, F., Navarra, G., and Pirrotta, A. (2014). Experimental validation of a direct pre-design formula for TLCD. Engineering Structures, Vol .75, pp. 528-538.
[23] ENGYS Ltd. (2016). HELYX-Core User’s Reference Guide - Release v2.5.x. Section 14.10, London, UK.
[24] Menter, F.R. (2011). Turbulence Modelling for Engineering Flows. ANSYS, Inc.
[25] Deising, D. (2015). Flux-Corrected Transport Algorithm in OpenFOAM – MULES. Center of Smart Interfaces, Mathematical Modeling and Analysis, Technische Universität Darmstadt.
Daniel Hung, Anthony Mosquera, Fluid-Structure Interaction of a Rigid Wing for Minesto Deep Green, a Tidal Energy Device, NAFEMS International Journal of CFD Case Studies, Volume 12, 2020, Pages 35-48, https://doi.org/10.59972/ef8rt5x2
Reference | CFDJ12-5 |
---|---|
Authors | Campos. F de Villiers. E Cammelli. S |
Language | English |
Type | Journal Article |
Date | 2nd February 2020 |
Organisations | ENGYS BMT Fluid Mechanics |
Order Ref | CFDJ12-5 Download |
---|---|
Non-member Price | £5.00 | $6.34 | €6.04 |
Stay up to date with our technology updates, events, special offers, news, publications and training
If you want to find out more about NAFEMS and how membership can benefit your organisation, please click below.
Joining NAFEMS© NAFEMS Ltd 2024
Developed By Duo Web Design